14
CLEARING MEMORY OF REMOTE CONTROLS
-
Clearing the remote control’s memory should be performed when
installing the drive. This ensures that the code of any remote control
other than the one owned by the owner is not stored in the drive's
memory.
-
If you lose the remote control, you should also clear the remote control
memory.
The deletion procedure is as follows:
Press and hold "C". When dLblinks, all remotes have been cleared.
REMOTE CONTROLS’ PROGRAMMING
The procedure for programming (logging in) the remote controls is as
follows;
1.
Briefly pressC, “Su” will be displayed.
2.
Press the selected key on the remote control twice - Su”/ will quickly
blink.
3.
Then “- -“ will be displayed to let you know that programming has been
successful.
-
A maximum of 20 remote controls can be logged in. If the display
shows "Fu", it means that the remotes memory is full. Then you need
to delete the remotes memory and log in only those that are used.
Depending on which functions of the drive we are going to use, the
order in which the individual buttons of the remote controls are logged
in will be different:
A.
If we use the drive without the lock function and without the
ventilation function, then we can log any remote control channel at any
time.
In this variant, one remote control can operate four gates.
B.
If we use a drive with a lock function, without a ventilation function,
then we can log the buttons “A, B, C” at any time. The "D" buttons of
the remotes are dedicated to unlocking.
C.
If we use the drive without the lock function, with the ventilation
function, then before activating the ventilation function, log the
buttons of all remote controls intended for ventilation (according to the
procedure, points 1-2).
When the ventilation function is turned on for the first time, the
buttons of all remote controls (other than those intended for the
ventilation function) are logged in for opening and closing the gate.
D.
If we use a drive with a lock and ventilation function, then logging the
buttons is as above, excluding the "D" button. After the remote control
deletion procedure has been carried out with the ventilation function
on, we first turn off this function and log all remotes to operate this