4. Operation
4.1. Before initial start-up
Engines are normally delivered without fuel and
oil.
4.1.1. Engine oil
Qualified are all trademark oils which fulfil at
least one of the following specifications:
ACEA – B2 / E2 or more significant
API – CD / CE / CF / CF-4 / CG-4 or more
significant.
If engine oil of a poorer quality is used, reduce
oil change intervals to 150 hours of operation.
Oil viscosity
5
Choose a viscosity according to the ambient
temperatures where the engine is to be started
from cold.
The engine must be in a horizontal position be-
fore adding oil or checking the oil level.
6
Pull out dipstick „1“ and add engine oil of the
correct specification and viscosity up to the
„max“ mark on the dipstick; (Chapter 3.1.).
4.1.2. Oilbath air cleaner
7
Take off the oil reservoir and fill it up to the
mark „1“ using engine oil.
Attach the oil reservoir, making sure that seal-
ing ring 2“ is correctly seated and catches „3“
are tight.
2393 / 6
2
3
1
1
-40
-30
-20
-10
0
10
20
30
40
50
10 4
86
68
50
32
14
-4
-22
-40
OIL: SAE...
°C°F
5W/30
5W/40
10W/40
10W/30
15W/40
30
40
122
10 W
10