2G40, 2G40 H Faults
HATZ
75Operator’s Manual
Possible causes Remedy Chapter
Mechanical faults. Contact HATZ Service.
With automatic electrical switch-off mechanism (option)
Possible causes Remedy Chapter
Stop signal of monitoring elements for:
No oil pressure. Check the oil level. 7.6 Check the oil
level, page 43
Faults in the AC al-
ternator or alternator
charging circuit.
Contact Hatz Service.
Engine temperature
too high.
Check the cooling air guides
for contamination or other im-
pairments.
8.2.8 Cleaning
the cooling air
area, page 64
Fault signal from the overvoltage and polarity protection system in
the voltage regulator:
Battery and/or other
cable connections are
incorrectly connected.
Check the electrical equipment
and its components or contact
Hatz service.
3.2.4 Electrical
equipment, page
18
Loose cable connec-
tions.
The engine loses power and speed
Possible causes Remedy Chapter
The speed adjustment
lever does not stay in
the desired position.
Block the speed adjustment.
The fuel supply is impaired:
The tank ran out of
fuel during operation.
Add fuel. 7.7 Refueling,
page 46
Fuel filter is clogged. Change the fuel filter. 8.2.10 Changing
the fuel filter,
page 67
Inadequate tank
venting.
Ensure that the tank is suffi-
ciently vented.
Air in the fuel sys-
tem.
Check the fuel system for air
ingress.
Check the bleed valve.