Maintenance 2G40, 2G40 H
52
HATZ
Operator’s Manual
Symbol Maintenance in-
terval
Maintenance step/check Chapter
Every 8–15 oper-
ating hours or ev-
ery day before
starting
Check the oil level. 7.6 Check the oil
level, page 43
Check the intake area of the
combustion air.
8.2.3 Check the
intake area of the
combustion air,
page 53
Check the cooling air area. 8.2.4 Checking
the cooling air
area, page 55
Check the engine oil level is
correct in the bottom section of
the oil bath air filter.
7.6.2 Oil level in
the oil bath air fil-
ter (option), page
45
250h
Every 250 operat-
ing hours
Change the engine oil and oil
filter.
8.2.5 Change the
engine oil and oil
filter, page 56
Clean the oil bath air filter. 8.2.6 Cleaning
the oil bath air fil-
ter, page 60
Check and set the tappet
clearance.
8.2.7 Checking
and setting the
tappet clearance,
page 62
Clean the cooling air area. 8.2.8 Cleaning
the cooling air
area, page 64
Check the screw connections. 8.2.9 Checking
the screw con-
nections, page
67
500h
Every 500 operat-
ing hours
Change the fuel filter. 8.2.10 Changing
the fuel filter,
page 67
Air filter service/dry air filter. 8.2.11 Maintain-
ing the dry air fil-
ter, page 69

Table of Contents