EasyManua.ls Logo

Hayward E-Vac - Troubleshooting - Intermittent Operation and Cord Twisting; Intermittent Operation Causes; Cord Twisting Prevention and Causes

Hayward E-Vac
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication Failure Causes
1. Damaged power supply, check for 21-25 volts DC
2. Water inside power connection to motor box,
check seal at motor box and for breaks in
flotation hose
3. Damaged flotation cord, check for ohms reading
of .4 to .8 ohms
DC voltage test on power supply
21 to 25 volts dc is acceptable. The power
supply is not repairable and must be replaced
if defective.
Insert voltage probes in pin terminal 1 and 2 and
turn on power supply to test.
Flotation cord test. Remove cord from
motor box and check ohm’s reading
between each pin and wire end. .4 to
.8 ohm’s is acceptable.
Testing Power Supply & Flotation Cord
Page 63

Related product manuals