EasyManuals Logo

Hayward SUMHEAT HP5131DT3 User Manual

Hayward SUMHEAT HP5131DT3
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
SUMHEAT
Full Inverter
V / Ph / Hz
Type
Type
kg
teqCO
2
/
kW
kW
A
/
kW
kW
/
A
aM
D
A
mm
m
3
/h
kPa
/
/
/
Ohm
/
mm
/
/
/
Tr/min
Tr/min
dB(A)
dB(A)
mm
kg
HP5171DT3 HP5211DT3
HP5301DT3
220 V - 240 V / 1 h / 50 Hz
HFC - R32 - (CH2F2)
A2L
0,8 1,35 1,65 1,8
0,54 0,91 1,11 1,22
Aucune exigence mais conseillé de façon annuelle
3,65 -- 17,05 6,35 -- 21,47 5,10 -- 24,30 7,74 -- 30,30
0,24 -- 2,47 0,46 -- 2,80 0,37 -- 3,79 0,59 -- 4,98
1,58 -- 10,78 2,81 -- 12,24 2,29 -- 16,57 3,48 -- 21,77
15 -- 6,89 13,66 -- 7,65 13,52 -- 6,41 13,03 -- 6,07
2,87 -- 12,63 4,76 -- 16,49 3,90 -- 18,96 5,53 -- 22,36
0,43 -- 2,41 0,64 -- 2,88 0,62 -- 3,78 0,86 -- 4,67
6,58 -- 5,24 7,49 -- 5,72 6,33 -- 5,01 6,45 -- 4,79
15,5 17,7 22,6 23
16 20 25 25
16 20 25 25
< CMS
50 mm
7,2 9,2 10,5 13,1
8 17 15 46
Mitsubishi Panasonic Panasonic Mitsubishi
Double Rotatif
1
0,95 0,88 0,88 0,49
Axial
1
522 560 560 600
3
DC Inverter
1
600 -- 700 500 -- 700 600 -- 750 500 -- 700
400
49,3 -- 51,8 55,9 -- 58,3 54,6 -- 59,9 56,8 -- 62,5
32,8 -- 35,1 40,3 -- 42,5 39,1 -- 44,4 41,7 -- 47,3
780 x 730 x 868 797 x 777 x 965
846 x 920 x 1024
75 101 101 123
HP5131DT3
0.65
0.44
3,66 -- 13,48
0,27 -- 1,92
1,70 -- 8,40
13.35 -- 6,99
2,
-- ,
0,43 -- 2, 1
, -- ,
16
16
Mitsubishi
0,95
522
-- 700
/
/
69
12
4
2. SPECIFICATIONS
2.1 Technical data for the swimming pool heat pump unit
(a) Dry air 27°C - Relative humidity 78% - Water inlet temperature 26°C.
(b) Dry air 15°C - Relative humidity 71% - Water inlet temperature 26°C
Models
Supply voltage
Refrigerant
Security unit
Load
Mass in teqCO
2
Leak check frequency
Min--Max heating capacity
(a)
Min--Max electric input power
(a)
Min--Max continuous current rating
(a)
Max--Min continuous power (COP)
(a)
Min--Max heating capacity
(b)
Min--Max electric input power
(b)
Max--Min continuous power (COP)
(b)
Maximum continuous current
Fuse rating
Circuit-breaker curve D
Starting current
Hydraulic connection
Nominal water flow
(a)
Max. loss of head on water
Compressor
Type
Quantity
Coil resistance at 20°C
Fan
Quantity
Diameter
Number of blades
Motor
Quantity
Rotation speed
Silent mode speed
Sound pressure level at 1 meter
Sound pressure level at 10 meters
Unit's net dimensions (L-W-H)
Weight

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward SUMHEAT HP5131DT3 and is the answer not in the manual?

Hayward SUMHEAT HP5131DT3 Specifications

General IconGeneral
BrandHayward
ModelSUMHEAT HP5131DT3
CategorySwimming Pool Heater
LanguageEnglish

Related product manuals