EasyManuals Logo

Hayward SUMHEAT HP5131DT3 User Manual

Hayward SUMHEAT HP5131DT3
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
6
2. SPECIFICATIONS (continued)
2.2 Operating range
Use the swimming pool heat pump unit within the following ranges of
temperature and humidity to ensure safe and efficient operation.
Heating mode Cooling mode
Outside temperature -15°C – +43°C +7°C – +43°C
Water temperature +12°C – +40°C +8°C – +40°C
Relative humidity < 80% < 80%
Setting range from the set point +15°C – +32°C +8°C – +32°C
If the temperature or humidity does not correspond to these conditions,
the security measures could be activated and the swimming pool heat
pump unit may no longer work.
The maximum heating temperature is set at 32°C to prevent damage to
the liners. Hayward cannot be held responsible if used at a temperature
above +32°C.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward SUMHEAT HP5131DT3 and is the answer not in the manual?

Hayward SUMHEAT HP5131DT3 Specifications

General IconGeneral
BrandHayward
ModelSUMHEAT HP5131DT3
CategorySwimming Pool Heater
LanguageEnglish

Related product manuals