T-CELL-15
GLX-CELL-15-W
NEW MENU SETTING MAY BE REQUIRED!
The T-CELL-15 and GLX-CELL-15-W are designed for pools up to 40,000 gallons. When
replacing an existing T-CELL-15 or GLX-CELL-15, no re-configuration is neccessary.
Configuration of your controller may be required before using the T-CELL-15 or GLX-CELL-15-W
chlorinator cell. Refer to the information below. Incorrect configuration will cause inaccurate salt
readings, improper operation, and possible system shutdown.
CONFIGURATION is necessary with the following models:
AQR (Aqua Rite - all 2009 or later) - firmware version 1.5 or later
AQR-PRO (Aqua Rite Pro)
PL-P-4 (Pro Logic P4)
PL-PS-x (Pro Logic PS)
AQ-LOGIC-P-4 (Pro Logic P4)
AQ-LOGIC-PS-x (Pro Logic PS)
NO CONFIGURATION is neccessary with the following models:
AQ-RITE (Aqua Rite - 2008 and earlier) - firmware earlier than version 1.5
AQ-RITE-XL (Aqua Rite XL)
Connecting to an AQR:
1. Slide the Main Switch to the "Auto" position.
2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the factory
default). If “t-15” is displayed, skip to step 4.
3. To change cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto".
Repeat this process until the “t-15” is displayed.
4. Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1. Access the Settings Menu by pushing the “Settings” button.
2. Push “>” until Chlor. Config is displayed, then push “+”.
3. Push “>” repeatedly until “Cell Type” is displayed.
4. Push “+” or “-” until “T-CELL-15” is displayed.
5. Exit Settings Menu by pushing the “Info” button.
Connecting to an AQ-LOGIC-P-4, AQ-LOGIC-PS-x, PL-P-4 or PL-PS-x:
1. Enter the Configuration Menu.
2. Push “>” until Chlor. Config is displayed, then push “+”.
3. With the Chlorinator Enabled, push “>” repeatedly until “Cell Type” is displayed.
4. Push “+” or “-” until “T-CELL-15” is displayed.
5. Exit Settings Menu by pushing the “Menu” button.
Question and Answer IconNeed help?

Do you have a question about the Hayward Turbo Cell and is the answer not in the manual?

Hayward Turbo Cell Specifications

General IconGeneral
BrandHayward
ModelTurbo Cell
CategoryLighting Equipment
LanguageEnglish

Summary

Chlorinator Configuration Procedures

Connecting to an AQR

Procedure for connecting the T-CELL-15/GLX-CELL-15-W to an AQR controller, including setting the cell type.

Connecting to an AQR-PRO

Steps to configure the T-CELL-15/GLX-CELL-15-W with an AQR-PRO controller via the settings menu.

Connecting to AQ-LOGIC/PL Systems

Instructions for configuring the T-CELL-15/GLX-CELL-15-W with AQ-LOGIC or Pro Logic controllers.

Important Information on Filtration and Flow

Chlorination Setting and Pump Run Time

Adjusting chlorination settings based on filter pump operating time for optimal chlorine production.

Low Flow Rate Precautions

Ensuring adequate flow to the salt cell, especially with variable speed pumps, to maintain efficiency.

Related product manuals