Adjusting the pump and fan output in Stand alone - use
a) Press the Mode-button at the control panel until a P and two figures will appear
on the LED-display.
b) Adjust the desired data (1 - 99%) by pressing the Up- or Down-button
c) Press the Mode-button again until an F and two figures will appear on the
display
d) With the Up- or Down-button the fan data can now be adjusted.
e) Press the Enter-button once to start the machine. The green Active-LED will be lit.
f) Stopp the machine by pressing the Enter-button again.
5.6 Use by internal programmable timer
With the internal programmable timer an individual profile for a show can be programmed. Two Levels
(Level A and B) with different pump and fan values and different run-times can be programmed (Level
A = settings 2, 3, 4 / Level B = settings 5, 6, 7). Also a pre-runtime can be programmed in (setting 1)
which tells the machine when it should start to run.
For example: The machine shall start to run after 30 Minutes (setting 1). Then
the stage should be filled with haze within 10 Minutes. Therefore a high pump
and fan output should be adjusted and a time of 10 Minutes (setting 2, 3, 4).
After 10 Minutes high output, pump and fan shall go down automatically to a
lower step and fill the stage with haze for another hour (setting 5, 6, 7).
The following Profile settings can be adjusted:
1. Pause (Pre-Runtime) 0 - 99 min
2. Pump (Level A) 1 - 99 %
3. Fan (Level A) 1 - 99 %
4. Run-Time (Level A) 0 - 99 min
5. Pump (Level B) 1 - 99 %
6. Fan (Level B) 1 - 99 %
7. Run-Time (Level B) 0 - 99 min
a) Press the Mode button repeatedly until „Pro“ will appear on the display.
b) Press the Enter button once to switch to the programmable timer Menu. The red Timer/
Profile-LED will be lit.
c) Adjust settings 1 to 7 according to the chart, using the Up/Down
buttons and pressing the Mode button to switch between the settings.
These settings are stored in non-volatile memory. You don‘t have to run the
Profile or press the Enter button in order to „save“ the settings. All settings
can be changed as described at any time.
d) To start the Profile with the adjusted values, press the Mode button, until
„run“ will appear on the display , then press the Enter button.
The Timer/Profile flashes, indicating that the Profile is running. The
green Active-LED will light as soon as the adjusted Pause (Pre-Runtime) has
passed and level A has started. The Profile can also be started via an optional
radio remote.
e) To leave the programmable timer menu or to quit the Profile, first press the Mode button until „ESC“
will appear on the display.Then press the Enter button once to
return to the main menu.