5.7 Use by internal timer
With the internal timer, the haze time and wait time can be adjusted in Minutes
(0.1 - 99), the pump and fan output can be adjusted in per cent (0 - 99).
To start the Timer-Mode, press and hold the Mode button for more than 2 Seconds. The red
Timer/Profile-LED will blink as soon as the machine has
switched to the Timer-Mode. As long as the timer is in operation, the red Timer/
Profile-LED blinks.
The adjusting of the output, haze time or wait time is the same as in the Standard-
Menu. This means you have to press the Mode button repeatedly until you
reach the required function.
With the Up/Down buttons you can adjust the required functions, then press
the Enter button to start the timer. Please note that P and F control Pump and
Fan, whereas P. and F. control Pause time and Haze (Fog) time.
The timer cycle starts with the time shown on the display when you press the
Enter button (i. e. P.xx = Starts with wait time, F.xx = Starts with haze time). The
timer cycle will not start if you press the Enter button while the pump or fan
output setting is shown on the display.
You can switch back to the Standard-Menu by pressing the Mode button
for more than 2 Seconds or by pressing the Mode button repeatedly until „ESC“ is shown on the
display and then press the Enter button once.
5.8 Auto start
If the timer is in operation and you disconnect the machine from the mains
cable, the base*hazer*pro will re-start in the Timer-Mode as soon as it‘s reconnected to
the mains. To stop this, press the Mode-button for more than 2 Seconds or by switching to „ESC“ in
the Timer-Mode and then press the Enter-button.
5.9 Wiring of the sockets
5pin XLR (DMX):
Pin 1 = Ground, Pin 2 = DMX , Pin 3 = DMX +
3pin XLR (analog):
Pin 1 = Ground, Pin 2 = 0-10 V + DC in, Pin 3 = 12 V + DC out, max. 50 mA
6. Cleaning and Care
Clean the fan grill in the flightcase from time to time to remove dust and dirt.
After several hours of operation, some droplets of condensation will have
formed at the nozzle. That is normal and not a malfunction.
!Please note: Remove fluid droplets at the nozzle only when the machine has
completely cooled off. During operation the nozzle gets very hot!
Do not let the base*hazer*pro run without any fluid as the pump will run dry.
Check the state of the fluid filter from time to time and clean or replace it
when necessary.
!PLEASE NOTE: The vaporizer of our machines does not have to be cleaned!
Cleaners, available on the market, can damage the vaporizer! We cannot grant
warranty in this case.