7. Troubleshooting
Trouble: The pump runs, but little or no haze is produced.
Cause: The pump sucks no or too little fluid.
Check whether the canister is empty
· Check whether the brass collar is properly connected with the brass coupling
Check whether the fluid filter in the canister is clogged
· Check whether the fluid tube is twisted or defective
Trouble: The yellow LED at the machine does not light up (only when running via DMX)
Cause: Connection from the machine to the desk is faulty.
Check whether the plug is plugged in correctly
Check whether the cable is defective
Check whether the DMX start address is adjusted correctly
Trouble: During operation the base*hazer*pro fails to work for a long time
Cause: The overtemperature protection device is activated.
Check whether the fan is clogged
Trouble: E-4 appears on the LED display
Cause: The machine is getting too hot. The heating
switches off and the machine cools down.
Solution: Disconnect the machine from the mains supply
for a moment and then re-connect it.
Trouble: E-8 appears on the LED display
Solution: The vaporizer is clogged.
Cause: Please send the machine to us
or your local dealer.
Trouble: E-1 appears on the LED display
Solution: Please send the machine to us
or your local dealer.
8. Technical data
Procedure: Haze machine without compressor
Power requirement: 1500 Watt
Voltage: 230 V/ 50 Hz
Warm up time: approx. 60 Seconds
Fluid tank capacity: 5 liters
Integrated Fan: > 6000 l/min.
Haze density: variable
Control: DMX 512
0 - 10 V analogue
cable remote (option)
Dimensions (L x W x H): 59,4 x 54 x 18,5 closed flightcase
41,4 x 54 x 18,5 open flightcase