24
([egusarsarr]
HRATHEIT®
.
[SS
aS
9
'
dans
ZT
RAT
Ry
Rie
PICTORIAL
11
Refer
to
Pictorial
11
for
the
following
steps,
\,
(-)
Turn
the
chassis
over
and
position
it
as
shown
in
Pictorial
11,
(N
Connect
a
1-3/4"
bare
wire
from
lug
3
of
coil
AX
(8-1)
to
lug
10
on
wafer
C
of
switch
BD
(8-1),
;
C)
Connect
a
2-1/2"
bare
wire
from
lug
2
of
:
coil
AX
(S-1)
to
lug
11
on
wafer
C
of
switch
BD
(S-1),
A)
Connect
a
3"
bare
wire
from
capacitor
AW
(S-2)
to
lug
12
on
wafer
C
of
switch
BD
(8-1),
(
pf)
Mount
a
#6
solder
lug
on
lug 2
of
variable
“capacitor
AU,
Secure
the
solder
lug
with
a
6-32
nut,
(#)
Connect
a
3"
bare
wire
from
lug
2
of
var-
'
iable
capacitor
AU
(S-1)
to
the
solder
lug
on
capacitor
AS
(S-1),
This
completes
the
assembly
of
your
Heathkit
HA~14
SSB
Linear
Amplifier,
Shake
out
all
wire
clippings
and
solder
splashes,
Check
to
be
sure
all
connections
have
been
properly
soldered,
Refer
to
Pictorial
12
for
the
following
steps,
(
)
Start
setscrews
into
the
remaining
two
knobs,
( )
Turn
the
TUNE
capacitor
until
the
plates
are
fully
meshed,
Install
a
knob
on
the
TUNE
capacitor
shaft
with
the
pointer
atthe
9
o'clock
position,
Refer
to
Detail
12A
for
the
following
steps,
(
)
Turn
the
outer
shaft
on
the
METER
control
fully
counterclockwise,
Install
the
lever
knob
on
the
outer
shaft
with
the
pointer
at
FWD,
Tighten
the
setscrew
with
the
allen
wrench
supplied,
Do
not
overtighten
or
the
outer
shaft
will
bend
causing
the
shafts
to
bind,
PICTORIAL
12