6.2 Matchine parameters which require optimization during commissioning and preliminary values
6.2.1 Common machine parameters for both ramp characteristics
Function
Parameter Possible
I I
No.
entry values
,Countiq direction X 20
i I
Oor 1
Y
21
Z
22
IV 23
Polarity of nominal
value voltage
X 24
Y 25
Z 26
Oor 1
IV 27
Software limit switch
of remaining nominal
value voltage with error
display
POSITIONING ERROR
ranges x+
X-
Y+
Y-
z+
Z-
Ivt
IV- 51
Analogue voltage with
52
44
45
46
47
48
49
50
- 30 000.000 . . .
+ 30 000.000 CmmJ
rapid traverse
Acceleration
54 0.001 . . . 1.5 [ml&J
1 as of software
Circular II~
Integral factor
X 28 0 . . .65
535
Y 29
Z 30
IV 31
Waiting time for cutout
185
0...65,535[s]
Preliminary
Optimised
entry values
entry values
0 .
0
0
0
+ 30 000.000
- 30 000.000
+ 30 000.000
- 30 000.000
+ 30 000.000
- 30 000.000
+ 30 000.000
- 30 000.000
_
9
Enter 0.2 if
machine-dependant
value is unknown
Enter 0.1 when
machine-dependent
value is unknown
9
51

Table of Contents