8.4.3 Clhecking and correction of axis-traversing and counting directions
Mains power on
t
Fault display:
POWER lNTIERRUPTED
cancel with CE
0
I
Emergency Stop routine
t
Display:
TRAVERSE OVER REFERENCE MARKS-
(sequence machine parameter no. 59)
Press “ext. Start”-button
I
NO NO
direction. First axis correct direction. First axis correct
t t
(corresponds to directions selected (corresponds to directions selected
with MP-Nos. 16 to 19) with MP-Nos. 16 to 19)
I
c
Press Ext. Stop Press Ext. Stop
--
I
r +
Switch over polarity of nominal
value voltage for appropriate axis
(MP Nos. 24 to 27)
+
YES
I
Axis stops after passing
over reference mark
I
Axis stands position looped
in random position
! 1 Mai:,;Er;ro-o:and 1
Fault display:
POWER INTERRUPTED
cancel with CE
q
The flow chart must be worked through for each axis!
t
The axis traversing direction is correct when it corresponds to the pro-
I
Emergency stop routine
I
grammed values (0. + direction, 1 . - direction) of machine
parameter 16, 17, 18 or 19, as per the machine directions given in
t
section 8.1.2).
Correct machine parameter
The counting direction is correct when it corresponds to the designated
20,21,22 or 23 (see section
machine (directions as per section 8.1.2.
8.1.3.1)
t
7’

Table of Contents