EasyManuals Logo

Heinzmann Programmer 2 User Manual

Heinzmann Programmer 2
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
5 Configuring the Governor with the Hand Held Programmer
28 Programmer PG 02
5.2.3.7 Automatic Adjustment of Actuator
5
ACT ADJ
After pressing this key, the instruction "Confirm actuator adjust! Press
ENTER to continue" is displayed. It is now possible to either carry out automatic
adjustment (autoadjust) or abort the procedure by pressing any other key. Automatic
adjustment may be performed only with the engine at a standstill.
If more than one actuators are connected to the governor, the hand held programmer
will offer a choice for which actuator automatic adjustment is to be performed.
Automatic adjustment of the actuator corresponds to adjusting feedback voltage for
an analogue governor.
5.3 Parameter Selection
5.3.1 Entering Parameter Numbers
NUMBER
END LIST
After pressing the [ENTER] key, the parameter number is replaced by a
blinking cursor, and the hand held programmer will be waiting for a number of
maximum four digits to be entered.
ENTER
Entry has to be terminated with the [ENTER] key. The parameters are
automatically included in the user mask. If a number has been entered that does not
exist in the governor, the parameter with the next higher number is selected. It is only
possible to select parameters that have been programmed for the previously set level.
CE
Input can be cancelled with the key [CE].
5.3.2 Selection by Arrow Keys
PARAM
PID
DISPLAY
ERRORS
FUNCT
SPEED
CURVES
DROOP
First, select the desired list with one of the keys
PARAM, DISPLAY, FUNCT or CURVES.
NEXT
LAST
By shortly pressing the arrow keys, one can then move on to the next
parameter or go back to the preceding one. Keeping the keys pressed permits to quickly
browse through the lists. By using the second functions, parameter selection becomes
considerably faster. The function [NEXT] performs a jump to the first parameter of the
next group, the function [LAST] a jump to the first parameter of the preceding group.
ON/OFF
BEGIN LIST
NUMBER
END LIST
The function [BEGIN LIST] performs a jump to the beginning of the list
and the function [END LIST] to ist end.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Heinzmann Programmer 2 and is the answer not in the manual?

Heinzmann Programmer 2 Specifications

General IconGeneral
BrandHeinzmann
ModelProgrammer 2
CategoryMotherboard
LanguageEnglish