15
EN
SAMPLE CONTROLLER PROGRAMMING:
If the keypad lock symbol is present on the display,
it has to be unlocked by pressing and holding up
the up [11] and down [12] button, until the key sym-
bol disappears.
1. In order to activate the setting change mode, the
Enter [9] button shall be pressed.
2. The [8] and [6] symbols will be lit in the settings
change mode. It will inform that the display shows
the current time. The colon (”:”) symbol will be
blinking between the indicator of hour and min-
utes.
3. In order to activate the current time change
mode, the enter [9] button shall be pressed.
The indication of time and the [8] symbol will start
blinking.
4. In order to adjust the indication of hours, the up
[11] and [12] down buttons must be pressed corre-
spondingly.
5. In order to confirm the setting selected, the en-
ter [9] button shall be pressed. The selected
indication will be accepted and the controller will
go to the minutes setting mode.
6. In order to adjust the indication of minutes, the
up [11] and [12] down buttons must be pressed
correspondingly. In order to confirm the setting se-
lected, the enter [9] button shall be pressed. The
controller will confirm changing the time with a
short sound signal and will return to the parame-
ters setting mode.
7. In order to move to another option, the down [11]
button shall be pressed.
8. In order to activate the mode of changing anoth-
er option, the enter [9] button shall be pressed.
The indication of time and the [8] symbol will start
blinking. With the down [11] and Up [12] button, the
desired value shall be chosen and confirmed with
the enter [9] button.
The controller will confirm changing the time with
a short sound signal and will return to the param-
eters setting mode.
9. In order to activate the setting change mode, the
enter [10] button shall be pressed.
Parameter Scope Unit of change
Current time 00:00-23:59 1
Regeneration type/operation mode A-01, A-02, A-03, A-04 -
Regeneration start time (only in A-01 and A-03 modes) 00:00-23:59 1
Volume of treated water between regenerations [m3] (only in
A-01, A-02 modes)
0 99.999 0.01
Volume of ion exchange resin in the container (only in A-03
and A-04 modes)
5 – 200 1
1 German degree =