TRANSPORTATION, HANDLING, INSTALLATION
34
6.1.3 Storage
If the compressor is to be stored before installation, do not open its package, and check the following
conditions:
The storage area temperature should be of 35
0
F (+2
0
C) and 110
0
F (+43
0
C).
The storage area should be dry, covered, shockproof, and resistant to the weather
conditions.
HERTZ COMPRESSOREN could be safely stored for maximum 6 months. If you are storing more
than 6 months, apply HERTZ COMPRESSOREN long term storage procedure.
6.1.4 Long Term Storage
6.1.4.1 Storage Preparation
Remove air intake filter and store in a clean secure area.
Drain oil from sump tank and plug.
Fill air end with the original lubricant as indicated by decal on the sump tank. Plug or blind flange
the inlet connection.
On water cooled packages, drain water from all coolers and piping and fill with 50/50 Glycol/Water
solution. Plug inlet and outlet connections. (Not required for air cooled machines).
On air side of coolers, moisture separators and traps, blowout with dry air to remove
moisture. Plug connections.
Blow control air lines with dry air to remove moisture. Seal or plug openings on blow-down valve
and relief valves.
Tag all plugs which must be removed before start-up.
Place desiccant in starter/control box. If the box has gasket door - check integrity for sealing;
correct if necessary. If the box does not have a gasket door, seal the box seams with moisture
resistant tape to prevent moisture ingress.
Megger motor. Record and place reading on a tag secured to the motor eye bolt.
Grease motor bearings.
Complete any additional storage requirements per the motor manufacturers recommendations.
Tape copy of storage instructions in plastic-envelope to outside of package or cover.

Table of Contents