23
3. Data plate
Heta A/S
Jupitervej 22 . DK-7620 Lemvig . Denmark
EN 13240:2001/A2:2004 - AEA - NS 3058/3059
Testrapport: 300-ELAB-2334-EN
SN No. 150835 06-2018
Ambition 5
Distance to combustible back wall: 200/150 mm
Distance to combustible at the side wall: 400 mm
Distance to furniture: 1100 mm
Average CO emission at 13% O
2
0,089%
Emission of CO in combustion products: 1110 mg/Nm
3
Average flue outlet temperatur: 200
o
C
Dust: 22 mg/Nm
3
Heat output: 4,9 kW
Engery efficiency: 85%
NOx 93 mg/Nm
3
OGC 62 mgC/Nm
3
Fuel Wood
The stove is approved for intermittent use.
Read the instructions carefully.
DOP Ambition 5 2334-2018
8058 002597-EN
Heta A/S
Jupitervej 22 . DK-7620 Lemvig . Denmark
EN 13240:2001/A2:2004 - AEA - NS 3058/3059
Testrapport: 300-ELAB-2335-EN
SN No. 150836 06-2018
Ambition 8
Distance to combustible back wall: 200/150 mm
Distance to combustible at the side wall: 400 mm
Distance to furniture: 1100 mm
Average CO emission at 13% O
2
0,077%
Emission of CO in combustion products: 968 mg/Nm
3
Average flue outlet temperatur: 250
o
C
Dust: 27 mg/Nm
3
Heat output: 4,9 kW
Engery efficiency: 80%
NOx 98 mg/Nm
3
OGC 22 mgC/Nm
3
Fuel Wood
The stove is approved for intermittent use.
Read the instructions carefully.
DOP Ambition 8 2335-2018
8058 000081-EN
Appendix A
The Clean Air Act 1993 and Smoke Control
Areas
Under the Clean Air Act local authorities may
declare the whole or part of the district of the
authority to be a smoke control area. It is an of-
fence to emit smoke from a chimney of a buil-
ding, from a furnace or from any fixed boiler if
located in a designated smoke control area. It
is also an offence to acquire an” unauthorized
fuel” for use within a smoke control area unless
it is used in an” exempt” appliance (” exempted”
from the controls which generally apply in the
smoke control area).
In England appliances are exempted by publi-
cation on a list by the Secretary of State in ac-
cordance with changes made to sections 20
and 21 of the Clean Air Act 1993 by section 15
of the Deregulation Act 2015. Similarly, in Scot-
land appliances are exempted by publication
on a list by Scottish Ministers under section 50
of the Regulatory Reform (Scotland) Act 2014.
In Wales and Northern Ireland these are autho-
rized by regulations made by Welsh Ministers
and by the Department of the Environment re-
spectively.
Further information on the requirements of the
Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implemen-
ting the Clean Air Act 1993 including designa-
tion and supervision of smoke control areas and
you can contact them for details of Clean Air Act
requirements
The Ambition 5 and 8 have been recommended
as suitable for use in smoke control areas when
burning dry wood logs.