2
Declaration of Performance EN
__________________________________________________________________________________________________________________________________
Regulation No. 305/2011
DOP-Scan-Line 8-2240-2017-EN
1. Unique identification code of product-type Stove
2. Product name Scan-Line 8 / Scan-Line 8 Side windows
3. Intended use or uses of the construction product, in
accordance with the applicable technical specification
Room heater burning solid fuel without hot water supply
4. Name and contact address of the manufacturer Heta A/S, Jupitervej 22, DK-7620 Lemvig. heta@heta.dk
5. Where applicable, name and contact address of
authorized representative. E-mail.
Martin Bach, E-mail: martin.bach@heta.dk
6. System of assessment and verification of constancy of
performance of the construction product
System 3
7. Notified body relevant to the assessment and
verification of constancy of performance
Teknologisk Institut, DK-8000 Aarhus
Notified body No. 1235
Rapport nr. 300-ELAB-2240-EN Rev. 1.
8. Declared Performance
Harmonized technical specification EN 13240:2001/A2:2004
Emission CO 0,05%/657 mg/Nm
3
Nox 99 mg/Nm
3
Dust <3 mg/Nm
3
Dust (NS3058/3059) 0,63 g/kg
OGC (CEN/TS 15883) 32 mgC/Nm
3
- 13% O
2
Fire safety
Reaction to fire A1
Test of fire safety in connection with the burning of wood Approved
Distance to combustible materials
Rear
Sides distance to combustible materials
Distance to floor from lower edge of the door
Furniture distance
Minimum distances in mm
(100) / 120 (With side windows)
(400) / 350 (With side windows)
150
(700) / 850 (With side windows)
Safety
Mechanical resistance (to carry a chimney / flue) Not tested (NPD)
Electrical safety NA
Surface temperature Approved
Cleanability No specification
Thermal output
Nominal heat output 4,5 kW
Room heat output 4,5 kW
Energy efficiency
Ƞ 81%
Fluegas temperature at nominal heat output T 261
o
C
Water heating output NA
Maximum water operating pressure NA
9.
The performance of the product identified in points1 and 2 is in conformity with the declared performance in point 8. This
declaration of performance is issued under the sole responsibility of the manufacturer.
Signed on behalf the manufacturer of 22.02.2017