4.9 Input configuration
4.9 Input configuration
The LD8 is capable of utilising corrections from external sources of Veripos RTCM (RTCM v2, RTCM v3
or CMR) and RTK correction data. For RTK solutions the position will be output in the datum of the
correction source.
4.9.1 Inputting external Veripos RTCM via terminal
To input external corrections, you must issue two commands to the unit. These two commands will
configure the required baud rate of input and then set the port for decoding of Veripos RTCM data. These
commands are SERIALCONFIG and INTERFACEMODE.
The example commands below show configuration of COM1 for input of Veripos RTCM data, with a baud
rate of 115200:
SERIALCONFIG COM1 115200 N 8 1 N OFF
INTERFACEMODE COM1 VERIPOS_RTCM NOVATEL ON
NOTE
The LD8 is preconfigured to receive RTK corrections. Only port and interface mode
settings need to be applied.