EasyManuals Logo

HID iCLASS R10 User Manual

HID iCLASS R10
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Guide
iCLASS Reader Models R10, R30, R40, RW300, RW400
An ASSA ABLOY Group company
ASSA ABLOY
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page - www.hidcorp.com e-mail – tech@hidcorp.com
iClass
™ Reader Installation Manual 6090-900 Rev 8 Page
1
of
3
PARTS INCLUDED SPECIFICATIONS
1 -
iCLASS
Reader
R10 (Mullion)……………..10 - 16VDC / 65-225mA
1 - Installation Manual
R30/RW300 (Euro)………10 - 16VDC / 80-260mA
2 - 3.5mm x .6 pitch x 12mm Phillips machine screws
R40/RW400 (US)………...10 - 16VDC / 80-260mA
3 - #6-32 x .375” Phillips self-tapping machine screws
Cable distance to Host…..Wiegand - 500 feet (152m) max
2 - #6 x 1.5” Phillips sheet metal screws RS-232 - 50 ft (15m)
1 - #6 x .375” Spanner security screw, anti-tamper
Temperature………………-35° C to 65°C
Recommended:
Open collector output…….sink - 40mA, source - 1mA
Up to 9 wire splices
Standards:
Cable, 5-9 conductor (Wieg. or RS232), 22awg shielded
Read/Write* capability in ISO 15693-2 mode with HID
Linear DC Power supply
iCLASS
credentials
Metal or plastic junction box
Read/Write* capability in ISO 14443-B2 mode with HID
Magnetic switch - Ademco 945T, Sentrol 1038T, GRI 100T
iCLASS
16Ks and other 3
rd
party credentials
or 110T or Aleph DC-2531
CSN read capability for ISO 14443-A1 with HID Mifare
Security Tool (for anti-tamper screw) HID 04-0001-03 and other 3
rd
party Mifare credentials
* R10, R30, R40 are read-only
INSTALLATION
1- Disassemble
2 - Lift Bottom of Bezel 4 - Lift top of Reader Assembly
1- Remove Screw
3 - Slide Bezel up and remove 5 - Slide down and remove
2- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm
system. (Except R10). Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
Electrical Back Box
Wall Surface

Other manuals for HID iCLASS R10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HID iCLASS R10 and is the answer not in the manual?

HID iCLASS R10 Specifications

General IconGeneral
ModeliCLASS R10
CategoryCard Reader
Frequency13.56 MHz
ColorBlack
Card CompatibilityiCLASS, MIFARE, DESFire
Operating Humidity5% to 95% non-condensing
InterfaceWiegand
Form FactorWall Mount
Power Supply5-16 VDC
WarrantyLimited Lifetime Warranty

Related product manuals