28
Device
Address
Class
Command
Address
Subclass
Command
Address
Read/Write
Standard
Attached
Data
Remark
0x36
0x7C
0x03
0x00
N/A
Manual Background Correction
Return:
Device
Address
Class
Command
Address
Subclass
Command
Address
Return
Standard
Attached Data
Remark
0x36
0x7C
0x03
0x03
N/A
3.8.3 DDE Detail Strength
DDE Detail Strength:
Device
Address
Class
Command
Address
Subclass
Command
Address
Read/Write
Standard
Attached Data
Remark
0x36
0x78
0x10
0x00
0 to 100, 50 by
default.
DDE Detail Strength
Return:
Device
Address
Class
Command
Address
Subclass
Command
Address
Return
Standard
Attached Data
Remark
0x36
0x78
0x10
0x03
N/A
3.8.4 DNR Spectral Level
DNR Spectral Level Adjustment:
Device
Address
Class
Command
Address
Subclass
Command
Address
Read/Write
Standard
Attached Data
Remark
0x36
0x78
0x15
0x00
0 to 100, 50 by
default.
DNR Spectral Level