4 DS-2CD7126G0/L-IZS
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
Step 3: Configure the Alarm Interval, Alarm Threshold and Waiting Time Detection
Settings for each region.
Advanced parameter meaning:
Alarm Interval: it’s set to avoid multiple repeated alarm. For instance, if this value is
set to 300s, the second alarm will not be triggered unless it’s 300s or longer after the
first alarm.
Alarm Threshold: Alarm will be triggered when the people in the detection region is
equal to or higher than the set value.
Waiting Time Detection Settings: Alarm will be triggered when the waiting time in the
detection region is equal to or higher than the set value.
People Queuing-Up OSD: Display the people numbers of each region on the video.
5. Report
You can get queue report on IP camera’s webpage or IVMS-4200. Take webpage as
example.
Queuing-Up Time Analysis
Queuing-Up Time Analysis calculates people number of different waiting time level.