Pre-Alarm: When the temperature of target exceeds the Pre-Alarm Threshold, and
this status keeps NOT shorter than the Filtering Time, it triggers the Pre-Alarm.
Check the checkbox of Pre-Alarm Output to set link the pre-alarm with the connected
alarm device.
Alarm: When the temperature of target exceeds the Alarm Threshold, and this status
keeps NOT shorter than the Filtering Time, it triggers the Alarm.
Check the checkbox of Alarm Output to set link the pre-alarm with the connected
alarm device.
4. Click Save.
Expert Mode:
1. Enter Configuration > Temperature Measurement > Advanced Settings.
2. Select the temperature measurement and alarm configuration as Expert.
3. Adjust the PTZ.
Figure 5-27 Temperature Measurement Configuration
1) Adjust the image to the scene for temperature measurement with the PTZ control panel.
Save current scene as certain preset.