Range [1s-10s], the threshold for the me of the object loitering in the region. When the
duraon of the object in the dened detecon area is longer than the set me, the alarm
will be triggered.
3)
Oponal: Set Detecon Target as Human or Vehicle to discard alarms which are not triggered
by human body or vehicle.
Note
This funcon is only available for certain models.
4) Click Max. Size and draw a quadrilateral in the preview window to set the maximum draw
area size of the target.
5) Click Min. Size and draw a quadrilateral in the preview window to set the minimum draw area
size of the target.
6) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes of
the
detecon region.
5.
Set the arming schedule. Refer to Congure Arming Schedule for details.
6.
Set the linkage
acons. Refer to Congure Alarm Linkage Acon for details.
7.
Click Apply.
Region Entrance
Detecon
For certain network cameras, region entrance detecon funcon detects people, vehicles or other
objects which enter a pre-dened virtual region from the outside place, and some certain acons
can be taken when the alarm is triggered.
Steps
1.
Go to
Conguraon → Event → Smart Event → Region Entrance .
2.
Set Camera.
3.
Turn on Enable.
4.
Oponal: Check Save VCA Picture to save the captured pictures of VCA detecon.
5.
Set the detecon rules and detecon areas.
1) Set Arming Area. Up to 4 arming areas are selectable.
2) Adjust
Sensivity. Sensivity: Range [0-100]. The higher the value is, the more easily the
detecon alarm can be triggered.
3) Oponal: Set Target Detecon as Human or Vehicle to discard alarms which are not triggered
by human body or vehicle.
Note
This funcon is only available for certain models.
4) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes of
the detecon region.
6.
Set the arming schedule. Refer to
Congure Arming Schedule for details.
7.
Set the linkage acons. Refer to Congure Alarm Linkage Acon for details.
8.
Click Apply.