EasyManua.ls Logo

HIKVISION DS-K1T343 Series - Page 98

HIKVISION DS-K1T343 Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud rate when the devices are communicang via the RS-485 protocol.
Data Bit
The data bit when the devices are communicang via the RS-485 protocol.
Stop Bit
The stop bit when the devices are communicang via the RS-485 protocol.
Parity/Flow Ctrl/Communicaon Mode
Enabled by default.
Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
1.
Tap
Conguraon → Access Control → Wiegand Sengs .
Figure 8-15 Wiegand Page
2.
Enable Wiegand to enable the Wiegand funcon.
3.
Set a transmission direcon.
Input
The device can connect a Wiegand card reader.
Output
DS-K1T343 Series Face Recognion Terminal User Manual