24
Stay Arm Bypass
The zone will be automatically bypassed in stay arming.
Cross Zone
PD6662 is not enabled: You need to set the combined time interval.
When the first zone is triggered, the system will start timing after the zone is restored. If the
second zone is triggered within the set time, both zones will give alarms. Otherwise, no alarm
will be triggered.
If the first zone is not be restored, both zones will give alarms when the second zone is
triggered, regardless of whether the set time has elapsed.
PD6662 is enabled: You need to set the combined time interval.
The first zone will give an alarm when triggered. If the first zone is not restored and the
second zone is triggered, the system will report the alarm confirmation.
If the first zone is restored, the system will start timing. If the second zone is triggered within
the set time, the system will report the alarm confirmation.
If the first zone is restored, the system will start timing. If the second zone is not triggered
within the set time, no information will be reported.
Forbid Bypass on Arming
After enabled, you cannot bypass zones when arming.
Chime
Enable the doorbell. Usually used for door magnetic detectors.
Silent Alarm
After enabled, when an alarm is triggered, only the report will be uploaded and no sound is
emitted.
Double knock
After enabled, the time interval can be set. If the same detector is triggered twice or
continuously in a period of time, the alarm will be triggered.
Sounder Delay Time
The sounder will be triggered immediately (0s) or after the set time.
Final Door Exit
Only magnetic contacts have this option.
After enabling, when the user use keypads or tags to arm:
-Arm With Faults is enabled: During the arming countdown, if the magnetic contact is
triggered and then restored, the arming process will be terminated immediately after
restoring, and the arming is completed.
- Arm With Faults is disabled: If the magnetic contact is triggered and then restored, the
linked area immediately arms the delayed zone.
Dual Zone
After enabled, when multi transmitter detects that the entire zone circuit of the local zone
and the extended zone is open circuit, both zones trigger lid opened alarms.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA64-LP/NP and is the answer not in the manual?

HIKVISION DS-PHA64-LP/NP Specifications

General IconGeneral
BrandHIKVISION
ModelDS-PHA64-LP/NP
CategoryControl Panel
LanguageEnglish

Related product manuals