5. Select a zone type.
Instant Zone
This Zone type will immediately trigger an alarm event when armed.
Delay Zone
Exit Delay: Exit Delay provides you time to leave through the defense area without alarm.
Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system
without alarm.
The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in
entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via
operating keyboard for users.
Note
You can set 2 different time durations in System Options Schedule & Timer.
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
You can set Stay Arm Delay Time for the delay zone.
Panic Zone
The zone activates all the time. It is usually used in the sites equipped with panic button,
smoke detector and glass-break detector.
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Keyswitch Zone
The linked area will arm after being triggered, and disarm after being restored. In the case of
the tampering alarm, the arming and disarming operation will not be triggered.
Note
Two trigger types (by trigger times and by zone status) can be selected for the zone. If the zone
status type is selected, set the trigger operation (trigger arming/disarming).
Disabled Zone
Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors.
24-Hour Zone
The zone activates all the time with sound/siren output when alarm occurs. It is usually used
in fire hazardous areas equipped with smoke detectors and temperature sensors.
Timeout Zone
The zone activates all the time. The zone type is used to monitor and report the "ACTIVE"
status of a zone, but it will only report and alarm this status after the programmed time has
expired. (1 to 599) Seconds. It can be used in places equipped with magnetic contacts that

Table of Contents

Other manuals for HIKVISION DS-PS1-I-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PS1-I-WE and is the answer not in the manual?

HIKVISION DS-PS1-I-WE Specifications

General IconGeneral
BrandHIKVISION
ModelDS-PS1-I-WE
CategorySecurity System
LanguageEnglish

Related product manuals