DS-TMG033 Barrier Gate Radar User Manual
16
Figure 3-3 Port Selection
The software automatically detects all available ports and you can click serial ports as needed.
Corresponding ports can be viewed in the computer device management.
Radar baud rate is set to 115200 bps, parity bit to odd, stop bit to 2 bits, and data bits to 8 bits
by default.
2) Click Connect after finishing configuration.
Step 4 Click Update Scene in menu bar, and click Yes in the pop-up dialog box.
Green indicator flickers during calibration, and make sure no pedestrians or cars pass in 5
seconds. Green indicator stops flickering in 5 seconds when the calibration finished.
When Update timeout pops up or scene changes, you have to conduct calibration again.
Step 5 Clear current count.
If you need to recount the traffic flow, click Clear Current Count, and click Yes in the pop-up
prompt to clear the traffic flow counting.
3.2 Configure Radar Parameters
Step 1 Configure parameters
The radar parameters to be configured is shown in figure 3-4, among which, Anti-smash
Zone Width, Fall Pole Delay, Distinguish Human and Car are only applicable to anti-fall radar.
For capture-trigger radar, you need to configure detect distance. Configure parameters as
needed.
Figure 3-4 Radar Parameters