Chapter 7 Serial Port Conguraon
7.1 Set RS-485
Set RS-485 parameters if the device needs to be connected to other peripheral devices controlled
by RS-485 serial port.
Before You Start
The corresponding device has been connected via the RS-485 serial port.
Steps
Note
The number of available RS-485 serial port varies with dierent models.
1.
Go to Conguraon → System → System Sengs → Serial Port → RS-485 .
Figure 7-1 Set RS-485
2.
Set Baud Rate, Data Bit, Stop Bit, etc.
Note
The parameters should be same with those of the connected device.
3.
Set Work Mode.
Note
●
The supported work modes vary with dierent models. The actual device prevails.
●
You need to reboot the device aer eding the work mode to take eect.
Applicaon Trigger
Select it when a signal trigger device (such as a radar) is connected to the RS-485 serial port
of the device.
Transparent Channel
Select it when the other peripheral device is connected to the RS-485 serial port of the device
for
communicaon transmission.
GPS
Select it when a GPS device is connected to the RS-485 serial port of the device to receive
posioning informaon.
4.
Click Save.
Network Trac Camera Operaon Manual
43