EasyManua.ls Logo

Hill-Rom P3930 - User Manual

Hill-Rom P3930
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER MANUAL
and Assembly Instructions
Hill-Rom®
100 Low Bed
Product No. P3930
147730 REV 2

Questions and Answers

  • D
    David ArmstrongAug 5, 2025
    What to do if my Hill-Rom Medical Equipment has no power?
    • A
      Adrian YoungAug 5, 2025
      If your Hill-Rom Medical Equipment isn't working and has no power, several factors could be at play. First, ensure the bed is properly plugged into the wall socket and that the battery is charged; if not, charge or replace it. Check if a circuit breaker has tripped and reset it if necessary. Also, verify that the control pendant is securely plugged into the bed. Make sure all foot-end lockouts are disengaged. Finally, if none of these steps work, the internal controller fuse might be blown, requiring replacement of the internal controller.
  • A
    Adam DelgadoAug 9, 2025
    Why head, knee, or foot section does not raise or lower on Hill-Rom Medical Equipment?
    • B
      Brad ReyesAug 9, 2025
      If the head, knee, or foot section of your Hill-Rom Medical Equipment isn't raising or lowering correctly, start by checking if any lockouts are engaged at the foot end of the bed and disengage them. Ensure that all cables are properly plugged into the controller. Inspect the area under the frame for any obstructions, and make sure that bedding or hoses aren't tangled within the bed frame; clear any obstructions or untangle any entangled materials. Lastly, check if the foot gatch is in place and remove it.
  • D
    Donald PrestonAug 14, 2025
    What to do if my Hill-Rom Medical Equipment stops working after a long time?
    • U
      uhillAug 14, 2025
      If your Hill-Rom Medical Equipment stops working after a long time of operation, it could be due to a tripped circuit breaker; in this case, reset the circuit breaker. Another possibility is thermal overload. If this is the case, unplug the bed and allow it to rest for 20 minutes. Then, plug it back in and fully raise and lower it to ensure it's operating correctly and is level.
  • M
    Mark HesterAug 18, 2025
    Why Hill-Rom Medical Equipment does not operate on battery power?
    • D
      Daniel MillerAug 18, 2025
      If your Hill-Rom Medical Equipment doesn't operate on battery power alone, the internal battery may need charging, so charge the internal battery. Alternatively, the battery fuse might be blown, requiring a replacement. If neither of these solutions works, the battery itself may need to be replaced.
  • A
    Ashley NealAug 22, 2025
    How to fix not level bed surface on Hill-Rom Medical Equipment?
    • J
      Joseph FordAug 22, 2025
      If your Hill-Rom Medical Equipment bed surface is not level, it could be due to overloading at one end; reduce the load on the overloaded end. Check for any obstructions under the frame, or bedding or hoses tangled within the bed frame, and clear them. Alternatively, after a long period of inactivity, fully raise and lower the bed to re-establish a level surface.
  • S
    Shawn HubbardAug 27, 2025
    What to do if siderail binds on Hill-Rom Medical Equipment?
    • S
      Stephen MorenoAug 27, 2025
      If the siderail on your Hill-Rom Medical Equipment binds or doesn't lock in the up position, check for any interference from bedding or hoses and remove it. If the siderail is damaged, it will need to be repaired or replaced.
  • J
    Jocelyn EstradaAug 30, 2025
    What to do if Hill-Rom Medical Equipment bed does not lower completely?
    • A
      Amy BaileyAug 31, 2025
      If your Hill-Rom Medical Equipment bed does not lower completely, check for any obstructions under the bed and remove them.

Summary

Document Symbols

Intended Use and Features

Compatible Mattresses and Accessories

Patient Characteristics

Bed Setup and Operation

Siderail Management

Instructions for siderail operation, installation, and safety precautions.

Bed Height and Articulation

Procedures for adjusting bed height, head, knee, and auto-contour sections.

Control Pendant Usage

How to install, use, and lockout functions on the control pendant.

Bed Component Assembly

Guides for installing bed end panels, brakes, and foot gatch.

Safety Features Operation

Information on patient restraints, battery backup, CPR, and Trendelenburg simulation.

Mattress and Cleaning Procedures

Safety guidelines for mattresses and instructions for bed cleaning and disinfection.

Inspection and Disposal

General Safety Guidelines

Bed Positioning Safety

Safety advice for positioning the bed, especially for unattended or at-risk patients.

Electrical Safety and Battery

Mattress Safety and Entrapment

Product Symbols and Specifications

Classification and Standards Compliance

Warning and Caution Labels

Assembly and Final Checks

Assembly Procedure

Detailed instructions for the physical assembly of the bed components.

Hill-Rom P3930 Specifications

General IconGeneral
BrandHill-Rom
ModelP3930
CategoryMedical Equipment
LanguageEnglish