*2235358*
2235358 English 25
Storage temperature
−20 ℃ … 40 ℃
Battery charging starting temperature
−10 ℃ … 45 ℃
4.3 Noise information and vibration values in accordance with EN
62841
The sound pressure and vibration values given in these instructions were
measured in accordance with a standardized test and can be used to
compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However,
if the power tool is used for different applications, with different accessory
tools, or is poorly maintained, the data can vary. This can significantly
increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times
when the tool is switched off, or when it is running but not actually being used
for a job. This can significantly reduce exposure over the total working period.
Identify additional safety measures to protect the operator from the effects
of noise and/or vibration, for example: maintaining the power tool and
accessory tools, keeping the hands warm, organization of work patterns.
Noise emission values
SID 2A12
Emission sound pressure level (L
pA
)
94 dB(A)
Uncertainty for the sound pressure level (K
pA
)
3 dB(A)
Sound power level, L
WA
105 dB
Uncertainty for the sound power level (K
WA
)
3 dB(A)
Total vibration
SID 2A12
Vibration emission value when tightening
screws/bolts and nuts of the maximum permitted
size (a
h
)
9.9 m/s²
Uncertainty for tightening screws/bolts and nuts of
the maximum permitted size
1.5 m/s²
5 Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or
before changing accessories.