(APPENDIX I) PARAMETERS TABLE | PAGE 71
Tabla 14
Screen Table
Parameter PSW Description Default value Range
1 3 Inhibition of buzzer 0
0: Buzzer enabled
1: Buzzer disabled
2 3
PD inhibition in inputs/outputs
menu
0
0: Enable PD activation
inI/O menu
1: Disable PD activation
inI/O menu
3 -
Enabling heating of display
(read-only parameter version DGT
version 4.45 or higher)
-
0: Disabled heating of display
1: Enabled heating of display
4..8 - Reserved -
9 3 Heater integral coefcient
1
5 0..255
10 3 Heater proportional coefcient
1
15 0..255
11 2 Heater target temperature
1
5 0..10
12 2 Contrast
1
5 0..255
1: Version 5.00 or later