Thank you for purchasing the HIOKI RM3542/3542-01 Resistance HiTester. This guide describes basic screen operations
and comparator setting procedures. Before using the instrument the first time, please read the operating manual.
RM3542, RM3542-01
RESISTANCE HiTESTER
Operation Guide
November 2009 Edition 1 RM3542A983-00 09-11H Printed in Japan
Select and change display screens and settings
C
omparator Results
(
COMP indicator LEDs)
H
i Measured Value is
above Upper limit
I
N Pass (meets criteria)
L
o Measured Value is
below Lower limit
Numerical value
entry and related
settings
Absolute or relative value
P
ower On/Off
Unlit: power off
(while power is not supplied)
Red light: power off
(while power is supplied)
Green light: power on
Measurement cable jacks
Decision criteria
Measurement decision criteria settings
(Comparator function)
REF% Decide by reference value and tolerance (%)
ABS Decide by specified threshold values
Measurement Screen
(MISC MEAS MEAS SETTINGS)
Measurement Settings
DELAY1 Adjust the delay from probing to trigger input
DELAY2 Adjust measurement object electrical response
INT(FAST/ MED/ SLOW) Make fine adjustment to integration time
CONT CHECK Contact check threshold settings
CONT IMP Contact Improver function settings
VOLT MONITOR Voltage level monitor function settings
CURRENT MODE Current mode setting (CONT/ PULSE)
(MISC DATA DATA SETTINGS)
Data Settings
AUTO MEMORY Turn Auto-Memory on/off
STATISTICS Statistical calculation on/off
DATA OUT Automatically output measured value
(MISC SYSTEM SYSTEM) System Settings
SET MONITOR Turn two-instrument setting comparison on/off
PROBE CHECK Turn probe short-circuit detection on/off
RETRY Retry function on/off
TRIG EDGE (External I/O) Set trigger rising/falling edge
EOM (External I/O) Set EOM (end-of-measurement) signal
INTERFACE Communications interface settings
LOW POWER Low-power resistance component measurement on/off
JUDGE BEEP Comparator beeper settings
KEY BEEP Key beeper on/off
CLOCK(Y-M-D) Set internal clock
LINE FREQ Set power source frequency
CONTRAST Adjust screen contrast
BACKLIGHT Adjust screen backlight
RESET Initialize
ADJUST Instrument Adjustment
Basic Settings Screen
Detailed Settings
Screens
TRG Change trigger source (INT/EXT)
RANGE Change range (100mΩ to 100MΩ)
SPEED
Change measurement speed (FAST/MED/
SLOW)
0ADJ Turn zero-adjust on/off
COMP Turn comparator on/off
LOCK Enable/disable key lock (OFF/FULL/MENU)
Measurement screen operations are
shown on the back of this sheet.
Screen Organization

Other manuals for Hioki RM3542

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hioki RM3542 and is the answer not in the manual?

Hioki RM3542 Specifications

General IconGeneral
BrandHioki
ModelRM3542
CategoryTest Equipment
LanguageEnglish

Related product manuals