Installation EAGLE20/30
Release
06
04/2014
33
For every working voltage to be connected, perform the following steps:
Remove the power connector from the device.
Connect the lines for the supply voltage to the + and - terminals.
With non-redundant supply of the mains voltage, the device reports a power
failure. You can avoid this message by changing the configuration in the
management, or, with power supply units of the same type, by feeding the
supply voltage in through both inputs.
2.5.3 Signal contact
For every signal contact to be connected, make sure the following
requirements are met:
The electrical wires are voltage-free.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
Connect the signal contact wires with the connectors of the terminal block.
Type of the voltages
that can be
connected
Specification of the working
voltage
Connections
DC voltage Rated voltage range DC
24 V ... 48 V
Voltage range DC incl.
maximum tolerances
18 V ... 60 V
+ Plus terminal of the working
voltage
− Minus terminal of the working
voltage
Table 10: Operating voltage characteristic value C: type and specification of the
supply voltage, connections