Installation OZD Profi 12M ...
Release
01
07/2017
41
OZD Profi G3a... / G4a... OZD Profi 12M G...
a
Meaning of the DIP switches DIP switch Function DIP switch Function
S1 - Mode S1 = 0 Mode 0 S2=0 Mode 0
S1 = 1 Mode 1 S2=1 Mode 1
S2 - Redundancy function S2 = 0 OFF S3=0 OFF
S2 = 1 ON S3=1 ON
S3 - Termination S3 = 0 CH2 not terminated - not relevant (Termination extern)
S3 = 1 CH2 terminated
S4 - Termination S4 = 0 CH2 not terminated - not relevant (Termination extern)
S4 = 1 CH2 terminated
S5 - optical Power / Distance S5 = 0 Network configuration: Standard S4=0 Network configuration: Standard
S5 = 1 Network configuration: Extended S4=1 Network configuration: Extended
S6 - optical Power S6 = 0 Without function - -
S6 = 1 Without function - -
S8 =1 Compatibility ON
S0, S5 = 0 Without function
S6, S7 = 0 in Position = 0
Table 4: Switch assignment of the OZD Profi 12M ... at S8=1 as a spare or expansion device for OZD Profi G3a, ...G4a, ...G3a-
1300 and...G4a-1300.