Installation OZD Profi 12M ...
Release
01
07/2017
43
4.4 Setting the operating mode and
transmitting power
Note:
– S1 does not have a function on OZD Profi 12M ... with only one electrical
interface.
– S7 does not have a function on OZD Profi 12M ... with only one optical
interface.
The following details only apply for the S8 default position (S8 = 0).
The DIP switch S0 is used to set the operating mode of the electrical port
CH1.
The DIP switch S1 is used to set the operating mode of the electrical port
CH2.
This applies exclusively to device variants OZD Profi 12M x22:
The DIP switches S2 and S3 are used to set the operating mode of the
optical port CH3.
The DIP switches S4 and S5 are used to set the operating mode of the
optical port CH4.
4.4.1 Setting the operating mode of the electrical ports
(CH1, CH2)
Operating mode: electrical ports (CH1, CH2) with segments
monitoring
CH1 is activated in this operating mode if S0 is in Position 0.
Applies to device variants with 2 electrical ports:
CH2 is activated in this operating mode if S1 is in Position 0.
CH 3
CH 4
CH 3
CH 4
CH 1
CH 2