4.4 Setting compatibility, operating mode and transmitting power
17
4 Setting Up
Version 2.4 04/07
4.4 Setting compatibility, operating mode and transmitting power
Please note:
The OZD Profi 12M … must be switched off when
changing the operating mode.
You can switch off the OZD Profi 12M … by, e.g.,
unplugging the 5-pin terminal block.
4.4.1 Setting the compatibility
The DIL switch S7 is used to switch the functional
compatibility to devices of the preceding generation
OZD Profi P3a, … P4a, … G3a, … G4a,… G3a-1300 and
… G4a-1300 either off or on. Default setting at S7 is
Position 0 (compatibility is switched off).
DIL switch S7 (compatibility) in
Position 0:
compatibility to
OZD Profi P3a, OZD Profi P4a,
OZD Profi G3a, OZD Profi G4a,
OZD Profi G3a-1300 and
OZD Profi G4a-1300
switched off
DIL switch S7 (compatibility) in
Position 1:
compatibility to
OZD Profi P3a, OZD Profi P4a,
OZD Profi G3a, OZD Profi G4a,
OZD Profi G3a-1300 and
OZD Profi G4a-1300
switched on
01
S 6
S 7
S 1
S 2
S 4
S 5
S 3
S 0
01
S 6
S 7
S 1
S 2
S 4
S 5
S 3
S 0
The functional compatibility to OZD Profi modules of
the preceding generation OZD Profi P3a, … P4a, … G3a,
… G4a, … G3a-1300 and … G4a-1300 is switched on
with the DIL switch S7=1.
This operating mode is required when operating this
module together with new devices.
Only turn switch S7 to Position 1 if the OZD Profi 12M …
is being used as a spare or expansion device in existing
networks in conjunction with OZD Profi of the preceding
generation, and a direct optical connection is to be
made.
The following illustrations show the switch assignment of
the OZD Profi 12M … at S7=1 for
as a spare device for as a spare device for
OZD Profi P3a OZD Profi G3a,
and OZD Profi G4a,
OZD Profi P4a OZD Profi G3a-1300
and
OZD Profi G4a-1300
OZD Profi 12M G11,
OZD Profi 12M G11-1300:
S2 reserved
OZD Profi 12M …
G11, G12,
G11-1300, G12-1300:
OZD Profi 12M P11,
OZD Profi 12M P12:
OZD Profi 12M P11:
S6 reserved
S7 = 1 Compatibility Mode ON
S0 Reserved
S3,S4 Reserved
S1 Mode Monitor
0 Line/Ring On
1 Line Off
0 Off
1On
S2 Redundancy
S7 = 1 Compatibility Mode ON
S0 Reserved
S1 Mode Monitor
0 Line/Ring On
1 Line Off
0 Off
1On
S2 Redundancy
S5 Output Power CH3
0 Standard
1 High
0 Standard
1 High
S6 Output Power CH4
S3 Distance
0 Extended
1 Standard
S4,S5,S6 Reserved

Related product manuals