EasyManua.ls Logo

Hirschmann PAT DS 85/0002 - Page 54

Hirschmann PAT DS 85/0002
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual DS 85
© Hirschmann Rev.G 10/05/15 190166_G.DOCXG
48
Error Code
Error
Possible Cause
Elimination
E11
Fallen below lower
limit value for
measuring channel
"length main boom"
Length potentiometer is
defective
Replace length
potentiometer, see
section Length Sensing
E12
Fallen below the
lower limit value in
the measuring
channel "pressure
piston side"
Pressure transducer is
defective.
Replace pressure
transducer, see section
Pressure Sensing
E13
Fallen below lower
limit value in the
measuring channel
"pressure rod side"
refer to E12
refer to E12
E14
Fallen below lower
limit value in
measuring channel
"force"
Force transducer
defective
Replace force
transducer
Replace sensor unit
E15
Fallen below lower
limit value in
measuring channel
"angle main boom"
Angle potentiometer
defective
Replace angle sensor,
see section Angle
Sensing
E16
Fallen below lower
limit value in
measuring channel
"angle 2"
Angle potentiometer
defective
Refer to E-15
E17
Fallen below lower
limit value "length
telescope I (+II)"
Length potentiometer
defective
Replace length sensor,
see section Length
Sensing
E1A
Fallen below lower
limit value in
measuring channel
"slewing angle 1".
Cable between the
central unit and the
slewing angle sensor
defective or loose.
Check cable as well as
plugs, replace, if need
be.
Slewing angle
potentiometer is defective
Replace slewing angle
sensor
E1B
Fallen below lower
limit value in
measuring channel
"slewing angle 2"
refer to E1A
refer to E1A
E21
Upper limit value in
measuring channel
“main boom length”
has been exceeded.
refer to E11
refer to E11