© Hirschmann Rev. G 10/05/15 190166_G.DOCXG
49
Error Code
Error
Possible Cause
Elimination
E22
Upper limit value in
measuring channel
“pressure piston
side” has been
exceeded
refer to E12
refer to E12
E23
Upper limit value in
measuring channel
“pressure rod side
has been exceeded.
refer to E12
refer to E12
E24
Upper limit value in
measuring channel
“force” has been
exceeded.
refer to E14
refer to E14
E25
Upper limit value in
measuring channel
“main boom angle”
has been exceeded.
refer to E15
refer to E15
E26
Upper limit value in
measuring channel
“angle 2” has been
exceeded.
refer to E16
refer to E16
E27
Upper limit value in
measuring channel
“length telescope I
(+II) has been
exceeded.
refer to E17
refer to E17
E2A
Upper limit value in
measuring channel
“slewing angle 1”
has been exceeded
refer to E1A
refer to E1A
E2B
Upper limit value in
measuring channel
“slewing angle 2”
has been exceeded
refer to E1A
refer to E1A
E31
Error in the system
program
The system program file
is defective.
Flash-EPROM defective
Upload valid system
software
Replace central unit
E37
Error in the logical
program flow
System program file is
defective
Flash-EPROM defective
Upload valid system
software
Replace central unit
E38
System program
and crane data file
do not match.
The system program in
the LMI does not match to
the programming in the
crane data file
Upload valid system
program file or the valid
crane data file
E39
System program
and load chart file
do not match
The system program in
the LMI and the
programming in the load
chart file do not match.
Upload valid system
program file or the valid
load chart file

Other manuals for Hirschmann PAT DS 85/0002