Service Manual DS 85
© Hirschmann Rev.G 10/05/15 190166_G.DOCXG
Error in the slewing
angle measurement
The difference between
the average of the
slewing angle and one of
the wipers of the slewing
potentiometer is out of the
tolerance
See section Slewing
Sensing
The selected rigging
condition is not contained
in the crane data file.
Select another rigging
condition
Check the programming
in the crane data file.
Error in the radius
determination
The computed radius is
too small (negative
deflection)
Check the programming
in the crane data file.
Operating mode
switchover with
load.
The operating mode on
the console has been
switched over with the
boom loaded.
Select operating mode
without load on the
boom
Short circuit in the
A2B switch circuit
Short circuit in the A2B
switch
Short circuit in the cable
to the A2B switch
Replace A2B switch
Replace cable to the
A2B switch
A2B switch circuit
disconnected
Disconnected cable in the
A2B switch
Disconnected cable to the
A2B switch
Connect or replace
cable in the A2B switch
Connect or replace
cable to the A2B switch
No valid A2B switch
status
Sensor wrong function
CAN bus delay
Replace A2B switch
Replace cable to the
A2B switch
Note:
If an error message is displayed which is not contained in above list, please contact the PAT service
department.