EasyManua.ls Logo

Hirschmann PAT DS 85/0002 - Page 57

Hirschmann PAT DS 85/0002
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Hirschmann Rev. G 10/05/15 190166_G.DOCXG
51
Error Code
Error
Possible Cause
Elimination
Can bus port in the
central unit defective
Replace the central unit
Blown fuse in console
Replace 2 amp fuse
E62
Error in the can bus
data transfer of the
pressure transducer
sensor unit
Cable between the
central unit and the
sensor unit defective or
not connected.
Check the cable to the
sensor unit (wiring
harness). See section
CAN-Bus
Communication
Blown fuse in console
Replace 2 amp fuse
Sensor unit is defective
Replace the sensor unit
E63
Error in the can bus
pressure transducer
sensor unit
The analog values of the
sensor unit are invalid
Replace the sensor unit
See section CAN-Bus
Communication.
E64
Error in the can bus
data transfer of the
length/angle sensor
unit
Cable between the
pressure transducer and
cable reel defective or not
connected.
Check the cable to the
sensor unit. See section
CAN-Bus
Communication
Sensor unit is defective
Replace the electronic
board in the cable reel,
see section CAN-Bus
Communication
E65
Error in the can bus
length/angle sensor
unit
Angle sensor defective
Replace the angle
sensor, see section
CAN-Bus
Communication
Length sensor defective
Replace the length
sensor, see section
CAN-Bus
Communication
Sensor unit is defective
Replace the electronic
board in the cable reel,
see section CAN-Bus
Communication
E66
Error in the can bus
data transfer of the
2
nd
length/angle
sensor unit
See E62
See E62
E67
Error in the can bus
of the 2
nd
length
/angle sensor unit
See E63
See E63
E68
Error in the can bus
data transfer of the
force sensor unit
See E62
See E62
E69
Error in the can bus
force sensor unit
See E63
See E63

Other manuals for Hirschmann PAT DS 85/0002