5. Technical data
General data
Operating voltage DC 18 to 32 V safe extra-low voltage (SELV) (redundant inputs decoupled)
Current consumption typ. 160 mA at 24 VDC (without data)
max. 350 mA at 24 VDC (with data)
Overload current protection at input non-changeable thermal fuse
Dimensions W x H x D 80 mm x 140 mm x 85 mm (3.15 in x 5.51 in x 3.35 in)
Mass 900 g (1.982 lb)
Ambient temperature 0 ºC to + 60 ºC (32 ºF to + 140 ºF)
Storage temperature - 40 ºC to + 80 ºC (-40 ºF to + 176 ºF)
Humidity 10% to 90% (non condensing)
Protection class IP 30
Radio interference level EN 55022 Class B
Interference immunity EN 50082-2
Network size
Transition TP-Port TP-Port F/O port F/O port
Propagation equivalent 190 m (623 ft) 260 m (853 ft)
Variability value 3 BT 3 BT
Transition TP-Port F/O port
Propagation equivalent 360 m (1.181 ft)
Variability value 6 BT
F/O port
Optical output power
Graded-index fiber 50/125 µm (average) min. -22,0 dBm max. -16,2 dBm
Graded-index fiber 62,5/125 µm (average) min. -19,0 dBm max. -12,4 dBm
Optical input power min. -33,0 dBm
TP line length (TP-Port TP-Port)
Length of a twisted pair segment max. 100 m (328 ft)
F/O line length (example)
50/125 µm fiber max. 2.600 m (8530 ft)
62,5/125 µm fiber max. 3.100 m (10170 ft)
Scope of delivery
RH1-TP/FL Optical/Electrical Twisted Pair Industrial Hub for ISO/DIN Rail incl.
terminal block for supply voltage
description and operating instructions
Order number
RH1-TP/FL – Optical Twisted Pair
Industrial Hub for ISO/DIN Rail 943 613-001
Accessories
Ethernet manual 943 320-011
Notes on CE identification
The Twisted Pair Industrial Hubs
for ISO/DIN Rail comply with the
regulations of the following Euro-
pean directive:
89/336/EEC
Council Directive on the harmoni-
sation of the legal regulations of
member states on electromagnetic
compatibility (amended by Direc-
tives 91/263/EEC, 92/31/EEC and
93/68/EEC).
Area used Requirements for
emitted interference interference immunity
Residential EN 50081-1: 1992 EN 50082-1: 1992
Industrial EN 50081-2: 1993 EN 50082-2: 1995
The product can be used in the residential
sphere (residential sphere, business and
trade sphere and small companies) and in
the industrial sphere.
The precondition for compliance with EMC
limit values is strict adherence to the con-
struction guidelines specified in this
description and operating instructions and
in the “Ethernet manual“.
The EU declaration of conformity is kept
available for the responsible authorities in
accordance with the above-mentioned EU
directives at:
Richard Hirschmann GmbH & Co
Network Systems Division
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Telephone ++49-7127-14-1538