TECHNICAL&SERVICE MANUAL V2.0
—MULTI-SPLIT TYPE AIR CONDITIONERS
R410A
Refrigerant
R410A
Refrigerant
R410A
Refrigerant
R32
Refrigerant
Models:
<Outdoor Unit>
AMW2-14U4RRA
AMW2-18U4RXA
AMW3-24U4RAA
AMW4-27U4RAA
AMW4-36U4RAA
2AMW-42U4RRA
2AMW-50URXA
3AMW-70U4RAA
4AMW-81U4RAA
4AMW-105U4RAA

Questions and Answers

  • M
    Michael CoxSep 23, 2025
    What to do if my Hisense Air Conditioner shows IPM and control board communication fault?
    • C
      Craig WeaverSep 23, 2025
      To address an IPM and control board communication fault in your Hisense Air Conditioner, you can try the following steps: * Reconnect the cable between the control board and the driver board. * Replace the communication cable between the control board and the driver board. * Replace the driver board. * Replace the control board.
  • C
    Courtney HarveyAug 23, 2025
    What to do for drainage protection in Hisense 3AMW-70U4RAA Air Conditioner?
    • J
      Jesse Shaw MDAug 23, 2025
      To troubleshoot a drainage protection issue with your Hisense Air Conditioner, follow these steps: 1. Check the drain hose for blockages or excessive height. 2. Inspect the water pump and replace it if it's faulty. 3. Reconnect the cable of the water level switch, referring to the wiring diagram. 4. Replace the water level switch. 5. Replace the control board.
  • L
    Linda PetersonAug 25, 2025
    How to fix communication fault between indoor and outdoor unit of Hisense Air Conditioner?
    • C
      claudiawagnerAug 25, 2025
      To resolve communication issues between the indoor and outdoor units of your Hisense Air Conditioner, try the following: * Reconnect the connection cable, referring to the wiring diagram. * Reconnect the communication cable. * Replace the communication cable. * Replace the indoor or outdoor control board. * Check the communication circuit, adjusting the DIP switch and short-circuit fuse. * Ensure you are using a suitable communication cable, referring to the user manual.
  • M
    Michael NealAug 26, 2025
    What to do if my Hisense 3AMW-70U4RAA Air Conditioner shows compressor overheat protector device?
    • S
      Sydney SmithAug 26, 2025
      If your Hisense Air Conditioner's compressor is overheating, you can try the following steps: 1. Reconnect the wiring of the overload protector. 2. Replace the overload protector. 3. Check for leakage at the welding points and recharge the refrigerant if necessary. 4. Add refrigerant. 5. Replace the expansion valve. 6. Replace the outdoor control board.
  • C
    Chris ChaneyAug 27, 2025
    What to do if my Hisense 3AMW-70U4RAA turns off for high pressure protection?
    • S
      Shelly UnderwoodAug 27, 2025
      To address a high-pressure switch issue or unit shutdown due to high-pressure protection in your Hisense Air Conditioner, try the following: * Reconnect the wiring to the high-pressure protector. * Replace the high-pressure protector. * Replace the outdoor control board.
  • S
    Sharon CooleySep 17, 2025
    How to fix Suction temperature sensor fault in Hisense 3AMW-70U4RAA Air Conditioner?
    • K
      Kenneth BrownSep 17, 2025
      To resolve a suction temperature sensor fault in your Hisense Air Conditioner, you can try: * Reconnecting the wiring of the suction temperature sensor. * Replacing the suction temperature sensor. * Replacing the outdoor control board.
  • C
    Carl MillerSep 14, 2025
    What to do if The outdoor DC fan motor (down fan motor) fault in Hisense 3AMW-70U4RAA?
    • R
      Ruth RussellSep 14, 2025
      To address the outdoor DC fan motor fault (down fan motor) in your Hisense Air Conditioner, you can try: * Reconnecting the wiring of the down DC fan motor. * Replacing the down DC fan motor. * Replacing the driver board of the fan motor. * Checking the outdoor fan to ensure it can run normally.
  • J
    Jasmine MatthewsSep 15, 2025
    How to fix Discharge temperature sensor fault in Hisense Air Conditioner?
    • G
      Gerald Adams IISep 15, 2025
      To resolve a discharge temperature sensor fault in your Hisense Air Conditioner, you can try: * Reconnecting the wiring of the discharge temperature sensor. * Replacing the discharge temperature sensor. * Replacing the outdoor control board.
  • P
    perryderrickSep 6, 2025
    What to do if my Hisense Air Conditioner shows voltage absent phase?
    • M
      Mary PageSep 6, 2025
      To resolve a voltage absent phase issue in your Hisense Air Conditioner, consider the following: * Check the wiring connection, referring to the wiring diagram. * Replace the outdoor control board.
  • M
    Mary CastilloSep 3, 2025
    How to fix outdoor coil temperature sensor fault in Hisense 3AMW-70U4RAA Air Conditioner?
    • D
      Dr. John Alvarez DDSSep 3, 2025
      To fix an outdoor coil temperature sensor fault on your Hisense Air Conditioner, you can try: * Reconnecting the outdoor coil temperature sensor. * Replacing the outdoor coil temperature sensor components. * Replacing the outdoor control board components.

Summary

1. GENERAL

1.1 Features

Details core features like compressor type, inverter technology, expansion valve, and power recovery.

1.2 Product lineup

Table showing Outdoor Unit types, models, and capacities.

1.3 Model identification

Explanation of the model nomenclature, detailing each character's meaning.

1.4 Working range

Details on power supply and operating temperature range for cooling and heating.

1.5 Product picture

Visuals of outdoor units with their respective types and capacities.

2. SPECIFICATIONS

2. Specifications

Covers outdoor unit performance, operating range, compressor model, brand, and electrical data.

3. OUTLINES AND DIMENSIONS

3. Outlines and Dimensions

Dimensional drawings and specifications for the 14K outdoor unit, including clearances.

4. ELECTRICAL DATA

4. Electrical Data

Electrical specifications including power supply, ELB, applicable voltage, and current.

5. CAPACITIES AND SELECTION DATA

5.1 Capacity characteristic charts

Cooling and Heating capacity charts for the 14K model based on temperatures.

5.2 Piping length correction factor

Correction factors for piping length, gas diameter, and tables for cooling/heating correction.

5.3 Correction factors according to defrosting operation

Correction factors for heating capacity based on outdoor temperature and defrosting operation.

6. SOUND PRESSURE DATA

6. Sound pressure data

Sound pressure level charts for 14K and 18K models, showing octave band sound levels.

7. REFRIGERANT CYCLE

7. Refrigerant cycle

Diagrams illustrating the refrigerant flow for 14K/18K and 24K/27K/36K models.

8. WIRING DIAGRAM

8.1 Electrical wiring diagrams

Wiring diagram and fault code diagram for 14K/18K models, including terminal connections.

8.2 Electric control board

Image and labeling of the electric control board for 14K/18K models, showing component connections.

8.3 Running Parameter Query

Explanation of how to use the digital display board and buttons to query running parameters.

8.4 Common Wiring

Diagrams showing common wiring connections between outdoor and indoor units for different models.

8.5 Sensor parameter

Table of resistance values for the outdoor compressor discharge temperature sensor at various temperatures.

9. PIPING WORK AND REFRIGERANT CHARGE

9.1 MAX. Refrigerant pipe length and height difference

Requirements for pipe diameter, length, and height difference limits for different models.

9.2 Oil trap

Guidelines for installing oil traps when the indoor unit is lower than the outdoor unit and height is over 5m.

9.3 Additional refrigerant charge

Tables specifying pre-charged refrigerant and additional charge needed based on pipe length.

10. CONTROL MODE

10. Control mode

Explanation of Cooling Anti-freeze, Heating Overload, Cooling Overload, and Discharge Temperature Protection.

11. TROUBLE SHOOTING

11.1 The method of identify fault codes

Instructions on how to check fault codes using LED indicators on the control board.

11.2 Fault codes

Table listing outdoor fault codes, descriptions, possible reasons, and how to deal with them.

Note 3:Overload in cooling mode

Table detailing root causes and corrective measures for overload in cooling mode.

Note 4:Over load in heating mode

Table detailing root causes and corrective measures for overload in heating mode.

Drive Fault Codes (14 K;18 K)

Table of drive fault codes, descriptions, and solutions for 14K/18K models.

Drive Fault Codes (24 K;27 K;36 K)

Table of drive fault codes, descriptions, and solutions for 24K/27K/36K models.

12. CHECKING COMPONENTS

12.1 Check refrigerant system

Flowcharts for testing the refrigerant system in cooling and heating modes, including pressure checks.

12.2 Check parts unit

Lists fan motor and compressor models for various outdoor unit capacities.

Hisense 3AMW-70U4RAA Specifications

General IconGeneral
BrandHisense
Model3AMW-70U4RAA
CategoryAir Conditioner
LanguageEnglish