This central controller is used for unified cooling, heating, drying and air supply, etc. of
the air-conditioners in the group/zone. For other functions and settings, please refer to the
details on the setting of functions in this manual.
1. Turning ON/OFF
To start operation
When pressing the ON/OFF button in off state,
the ON indicator lights up and the starting
command will be sent to air conditioners in the
group/zone.
To stop operation
When pressing the ON/OFF button in on state, the
ON indicator turns off and the shutdown command
will be sent to air conditioner in the group/zone.
At this time, the set weekly timer ON (if any) will
take effect.
To completely shut down
Hold down "ON/OFF" button for more than 3
seconds, the central controller will enter completely
shutdown state (at this moment, the timer ON is
disabled and the appliance only can be started
manually), the ON indicator turns off, and shutdown
command will be sent to air conditioners in the
group/zone.
2. Mode setting
Press“MODE” button to select the desired operation mode in ON state, or OFF state with timer set.
Once the MODE button is pressed, the operation mode is changed in sequence:
3. Temperature setting
Press “ ”or “ ”button to set desired temperature in ON state, or in OFF state with timer set.
Then the temperature setting will blink on the LCD, indicating entering setting mode.
Each time “ ” button is pressed, temperature setting rises by 1C.
Each time “ ”button is pressed, temperature setting lowers by 1C.
Setting temperature is finished 3 seconds after setting temperature value blinking.
16
30 18 ~32℃/
Range of temperature setting
*Cooling, heating, drying
Fan only
Unable to be set
1. The ON/OFF button of central controller is only used to change the ON/OFF state of the air
conditioners in the group/zone without affecting the other settings.
2. When the wired controller (if any) for the group/zone receives the shutdown command from
the central controller, the appliance will enter completely shutdown state.
~
9
*: Note: Heating mode is unavailable for COOLING ONLY models.
Simple Operation
COOLING
HEATING
FAN ONLY
DRY
1
2