How to change the LPAR manager system time zone
Enter new system time zone on the sub-screen which is displayed on the
Date and Time screen by pressing F7 key.
Note:
LPAR SEL time zone has to be equal to LPAR manager system time zone.
If they are not equal, a wrong time is displayed on LPAR SEL time. The
correct time cannot be recognized if a failure has occurred.
Shutdown all the guest OS.
Place the cursor on LPAR RTC on the Date and Time screen and press
Enter to display a sub-screen. Select LPAR SEL Time and press Enter.
Figure 7-69 Changing the LPAR manager System Time-zone
Place the cursor on Time Zone on the Date and Time screen and press
Enter to display a sub-screen. Set a "Time Zone" and press Enter.
Figure 7-70 Setting of the Time-zone
Place the cursor on Setting on the Date and Time screen and press Enter
to display a sub-screen. Select LPAR RTC and press Enter.
Operation by LPAR manager Screen
7-103
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide

Table of Contents