Hitachi Compute Blade 500 Series
System Service Manual
MK-91CB500004-30
Document Organization
Product Version
Getting Help
Contents

Table of Contents

Questions and Answers

  • T
    Tamara BautistaAug 13, 2025
    How to fix Hitachi Server web console that does not start?
    • A
      ambersummersAug 13, 2025
      If the web console doesn't start, verify the connection between the management module and your console PC. Try reconnecting or replacing the LAN cable. You can also try typing the IP address into the web browser again.
  • Y
    ybradleyAug 16, 2025
    What to do if the Hitachi Server Power LED is off or blinking amber and the console reports AC failure?
    • T
      Tiffany WilliamsAug 16, 2025
      If the Power LED is off or blinking amber and the console reports AC failure, first verify that the power cord is properly connected to both the failed power supply and the AC source. If the issue persists, remove the failed power supply and replace it with a spare. If the Power LED lights up green after replacing the power supply, the process is complete.
  • E
    Eric HendersonAug 20, 2025
    Why is the Power LED of one power supply on my Hitachi Server solid amber and the console reports a power failure?
    • C
      christinachambersAug 20, 2025
      If the Power LED of one power supply is solid amber and the console reports a power failure, it indicates a power supply fault. Remove the failed power supply module and replace it with a spare. If the Power LED lights up green after the replacement, the process is complete.
  • A
    Austin AdamsAug 25, 2025
    What to do if the Active LED on my Hitachi Server is off or solid amber and the console reports a FAN failure?
    • J
      Joshua RodriguezAug 25, 2025
      If the Active LED is off or solid amber and the console reports a FAN failure, remove the failed fan module. Inspect the connector visually for damage. Reinstall it into the original bay. If the Active LED lights up green, the replacement is complete.
  • V
    Valerie RivasAug 27, 2025
    Why are the Power LEDs of all power supplies on my Hitachi Server solid amber, and the console reports Power failure?
    • K
      Kelly SalinasAug 27, 2025
      If the Power LEDs of all power supplies are solid amber and the console reports Power failure, disconnect all power cords. Remove all power supplies and modules installed in the server chassis, and check all the connectors for damage.
  • B
    Brittany HoffmanAug 31, 2025
    What to do if a Hitachi Server blade does not power up and all LEDs are off?
    • M
      Ms. Brittany WallAug 31, 2025
      If a server blade does not power up and all LEDs are off, remove the suspected server blade. Inspect the connector for damage. If there is no damage, install it into the original bay again.
  • A
    Andrew DuncanSep 4, 2025
    What to do if the Hitachi Server Power LED doesn't stop blinking in green for more than 10 minutes, or the HEARTBEAT LED is off or solid green?
    • A
      Allen TuckerSep 4, 2025
      If the Power LED does not stop blinking in green for more than 10 minutes, or the HEARTBEAT LED is off or is solid green, push the Shutdown switch for about 4 seconds to power off the suspected management module. Wait for one minute, then push the Shutdown switch again to power it up.
  • Z
    zrivasSep 8, 2025
    How to fix a Hitachi Server switch module that doesn't power up and the Power LED is off?
    • T
      Tammy ShawSep 8, 2025
      If a switch module doesn't power up and the Power LED is off, remove the suspected switch module. Inspect the connector for damage. If there is no damage, install it into the original bay again.