No. Name State Description
Amber-On An alarm state is detected
4 FC ports 16- 23 - These connectors are equipped with optical
modules (SFP+). Connect a fibre channel cable
to this optical module.
5 FC port status LED Green-On FC port online.
Green Blink Blink slowly: The FC port is online but
segmented
Blink rapidly: The port is diagnosed with the
internal loop-back.
6 FC port diagnosis LED Amber-On Signal is received but not on line.
Amber-Blink Blink slowly: The port is disabled.
Blink rapidly: The port fails.
Brocade 10Gb DCB switch module
Figure 1-47 Brocade 10Gb DCB switch module
Table 1-39 LEDs and connectors on 10Gb DCB switch module
No. Name State Description
1 Status LED Green-On Normal operation.
Green-Blink During power-on diagnosis or software
activation.
Amber-On A serious failure detected. (Flashing during
LED test of power-on diagnosis, it is not a
failure.)
Amber-Blink The warning detected. (The switch operates,
but the function is reconfigured and the
temperature threshold is exceeded.)
Off The power fails or no power is supplied.
2 Power LED (PWR) Green-On Power-on and normal operation.
Off The power fails or no power supplied.
3 Identify LED (LOCID) Blue-On The switch module is identified
Off The switch module is not identified
1-36
Introduction
Hitachi Compute Blade 500 Series System Service Manual