Figure 5-104 Removing the lithium battery- CB 520H A1/B1/B2/B3/B4
WARNING: To reduce the risk of the personal injury, do not attempt to
recharge the battery and do not crush, puncture or dispose of in fire.
CAUTION: Do not dispose the battery along with general household
waste. Use a public collection system, or return it to the Hitachi Data System
Support for recycling or proper disposal.
Installing a lithium battery
1. Put on an anti-static wrist strap.
2. Reverse the removal procedure.
3. In case of CB 520A A1 and CB 520H A1/B1/B2, if mezzanine card #2
installed then remove it.
See Replacing a mezzanine card in half-wide server blade on page 5-49
section.
4. Set the DIP switch #3 (RTCRST) to the ON position and then wait at
least ten seconds.
Figure 5-105 DIP switch #3 of CB 520A A1
Replacing parts
5-87
Hitachi Compute Blade 500 Series System Service Manual