Loading...
Message Content LP detected PCI bus error for Shared FC at expansion card.
Explanation A PCI bus fault in shared FC was detected.
What to do Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
Message Content LP detected reduction of CPUs.
Explanation LPAR manager detected reduction of the number of physical
processors.
What to do Back up the LPAR manager configuration and exit safe mode.
Check whether physical processors are isolated.
If you cannot resolve the problem, contact your reseller or
maintenance personnel.
Message Content LP detected reduction of memory.
Explanation LPAR manager detected reduction of the memory size.
What to do Back up the LPAR manager configuration and exit safe mode.
Check whether memory is isolated.
If you cannot resolve the problem, contact your reseller or
maintenance personnel.
Message Content LP detected uninitialized Shared device.
Explanation A shared I/O device that has not been initialized was detected.
What to do Contact your reseller or maintenance personnel.
Message Content
LP detected unsupported version of firmware on a NIC
device.
Explanation Unsupported firmware version was detected on a NIC device.
What to do Check the NIC firmware version is supported or not. If this action
takes no effect, contact the reseller from which you purchased
this equipment or consult maintenance personnel.
Message Content
LP failed to get Personality and Multichannel Mode on a
NIC device.
Explanation LPAR manager failed to obtain the Personality setting and
Multichannel mode from the NIC device.
What to do Reboot the LPAR manager. If this LP system log is collected after
rebooting, contact the reseller from which you purchased this
equipment or consult maintenance personnel.
Message Content LP failed to get the firmware version on a NIC device.
Explanation Retrieving the firmware version from a NIC device failed.
Messages